Operating Voltage: DC 10V to 24V
Electrical Impulse: ON: Lock
OFF: Unlock
Wiring: 2 wire Regardless + or –
Operating Voltage: DC 10V to 24V
Electrical Impulse: ON: Lock
OFF: Unlock
Wiring: 2 wire Regardless + or –
Description
details
| Model | LB12 | LB22 | LB35 |
| Photo | |||
| Operating Voltage | DC 10V to 24V | DC 10V to 24V | DC 10V to 24V |
| Starting: 1A ± 10% Operating: 110mA ± 10% |
Starting: 1A ± 10% Operating: 110mA ± 10% |
Starting: 1A ±10% Operating: 110mA ±10% |
|
| Electrical Impulse | ON: Lock OFF: Unlock |
ON: Lock OFF: Unlock |
ON: Lock OFF: Unlock |
| 5 wire | |||
| Red: + | |||
| 2 wire | 2 wire | Black: – | |
| Wiring | Regardless + or – | Red: + | Yellow: Exit button |
| Black: – | (work with Black) | ||
| White: Door sensor,COM | |||
| Blue: Door sensor,NO | |||
| Lock Delay | N / A | 0s,3s,or 6s(adjustable) | 0s,3s,or 6s(adjustable) |
| 6s | 6s | ||
| (automatically locks the | (automatically locks the | ||
| Unlock Delay | N / A | door again when no one | door again when no one |
| pushes the door within 6s | pushes the door within 6s | ||
| after unlocking) | after unlocking) | ||
| Door Sensor | N / A | N / A | Supports |